Home » MTP 5601 Clamp-On Ground Resistance Meter
MTP 5601 Clamp-On Ground Resistance Meter
Shipping Information:
Arrives:
Feb 19
Arrives:
Arrives:




The Clamp-on Ground Resistance Tester 5601 measures ground rod and small grid resistance through any season, without the use of auxiliary ground rods.
Clamp-on Ground Resistance Testers are used in multi-grounded systems without disconnecting the ground under test. The Model 5601 simply clamps around the ground conductor or rod and measures the resistance to ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.
- Non-Contact Ground Resistance Measurement
- No Auxiliary Electrode Needed
- 0.025 - 1500
- Ground Wire O 23mm/0.9inch
- Leakage Current (0.200mA - 10.00mA)
- Hi-Lo Alarm (Go - No Go)
- 116 Test memory locations
- Programmable data logging
The Bad:
The Bottom Line:
Full Review
- Measure electrical ground rod and grid resistance
- Use on multi-grounded systems without disconnecting the ground rod under test
- Measure resistance and continuity of grounding loops around pads and buildings
- Measure leakage current flowing to ground or circulating in ground systems
- Conduct field surveys and retrieve and analyze readings at a later time
- Use on cell towers and telecommunication sites
- Use on pools, spas and other consumer installations
- Non-Contact Ground Resistance Measurement
- No Auxiliary Electrode Needed
- 0.025 - 1500 Ohms measurement range
- Ground Wire O 23mm/0.9 inch¯
- Leakage Current (0.200mA - 10.00mA)
- Hi-Lo Alarm (Go - No Go)
- Memory of 116 records
- Programmable Data Logging
- Auto Detect of Jaw Open and Ground Noise
- Compliant with Safety Standard EN61010-2
- CAT II 600V , CAT III 300V
| General Specifications: Jaw Opening: 23mm (0.9 inch¯) Power Source: 9V Battery Power Consumption: 40mA Operating Temperature: 0°C to 40°C Operating Humidity: Less than 80% RH Dimensions: 258mm(L) x 100mm(W) x 47mm(H) 10.2¯(L) x 4¯(W) x 1.9¯(H) Weight: 640g (1.4lbs) Electrical Specifications: Ground Resistance (Autorange): Range
Resolution
Accuracy of reading1
1 Loop resistance noninductive, external field < 50A/m, external electrical field < 1V/m, conductor centered. 2 Resistance Measurement Frequency: 1.667KHz |
Continuity Beep if resistance < 40.00Ohm (Approximately) Ground / Leakage Current (Autorange, 50/60Hz, True RMS, Crest Factor < 3.0) Range
Resolution
Ground / Leakage Current (50/60Hz, True RMS, Crest Factor < 3.0) Range
Resolution
Accuracy of reading1
|


Yes! Available up to 