Home » Analog Fall of Potential » Analog Fall-of-Potential » Fluke 1623 Basic GEO Earth Ground Tester Kit
Fluke 1623 Basic GEO Earth Ground Tester Kit
Part Number:
FE 1623-KIT
In Stock?
Yes! Available up to 4 units Quantity
Price:
$2495.95
USD (change)
Shipping Information:
Ships in 1 - 3 Days
Arrives:
Arrives:
Feb 13-
Feb 19
Max of 4 unitsFeb 19
$62.50
Fast: Ships tomorrow*
Arrives:
Arrives:
Feb 10
Max of 4 units
$87.50
Fastest: Overnight
Arrives:
Arrives:
Feb 09
Max of 4 units
$115.00




The Fluke 1623 is perfect for performing predictive maintenance checks of commerical and industrial applications.
The Fluke 1623 is an all-in-one earth ground tester, offering 'one-button' simplicity. Not only measure ground resistance using the classic 'fall of potential test' but also enable time saving testing using the 'selective' and 'stakeless' methods. 'Selective' testing does not require the electrode under test to be disconnected during the measurement, thus increasing safety. The simple 'stakeless' method quickly checks ground connections using two current transformers (probes) clamped around the ground conductor under test.
Testing Methods
Earth ground resistance and soil resistivity should be measured when:
The Fluke 1623 is the stand-alone unit
For an advanced model see the Fluke 1625
What's Included:
The Fluke 1623 is an all-in-one earth ground tester, offering 'one-button' simplicity. Not only measure ground resistance using the classic 'fall of potential test' but also enable time saving testing using the 'selective' and 'stakeless' methods. 'Selective' testing does not require the electrode under test to be disconnected during the measurement, thus increasing safety. The simple 'stakeless' method quickly checks ground connections using two current transformers (probes) clamped around the ground conductor under test.
Testing Methods
- 3- and 4-Pole Fall of Potential – standard earth ground testing using two ground stakes
- 4-Pole Soil Resistivity testing – determine soil resistivity using four ground stakes
- Selective testing – without disconnecting ground rods, a technician can measure ground resistance using a combination of stakes and a clamp.
- Stakeless testing – innovative solution using only clamps, instead of ground stakes, to measure earth ground loop resistance.
Earth ground resistance and soil resistivity should be measured when:
- Designing earth ground systems
- Installing new ground system and electrical equipment
- Periodically testing ground and lightning protection systems
- Installing large electrical equipment such as transformers, switchgears, machines, etc.
The Fluke 1623 is the stand-alone unit
For an advanced model see the Fluke 1625
What's Included:
- Fluke 1623 tester
- 2 test leads
- 2 alligator clips
- 4 earth ground stakes
- 3 cable reels with wire (2-25 m, 1-50 m)
- selective/stakeless clamp set (one inducing, one sensing)
- Batteries
- Users manual
- Rugged carrying case
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- One-button measurement concept
- 3- and 4-pole earth ground measurement
- 4-Pole soil resistivity testing
- 2-pole resistance measurement AC
- Selective testing, no disconnection of ground conductor (1 clamp)
- Stakeless testing, quick ground loop testing (2 clamps)
- Measuring frequency 128 Hz
| RA 3-pole ground resistance measurement (IEC 1557-5) | ||
| Measuring Voltage |
| |
| Short circuit current |
| |
| Measure frequency |
| |
| Resolution |
| |
| Measuring range |
| |
| Intrinsic error |
| |
| Operating error |
| |
| RA 4-pole ground resistance measurement (IEC 1557-5) | ||
| Measuring Voltage |
| |
| Short circuit current |
| |
| Measure frequency |
| |
| Resolution |
| |
| Measuring range |
| |
| Intrinsic error |
| |
| Operating error |
| |
| RA 3-pole ground resistance measurement with current clamp | ||
| Measuring Voltage |
| |
| Short circuit current |
| |
| Measure frequency |
| |
| Resolution |
| |
| Measuring range |
| |
| Intrinsic error |
| |
| Operating error |
| |
| RA 4-pole selective ground resistance measurement with current clamp | ||
| Measuring Voltage |
| |
| Short circuit current |
| |
| Measure frequency |
| |
| Resolution |
| |
| Measuring range |
| |
| Intrinsic error |
| |
| Operating error |
| |
| Stakeless ground loop measurement | |||
| Measuring Voltage |
| ||
| Measure frequency |
| ||
| Noise current (Iext) |
| ||
| Resolution |
| ||
| Measuring range |
| ||
| Intrinsic error |
| ||
| Operating error |
| ||
| Environmental Specifications | |||
| Working temperature |
| ||
| Operating Temperature |
| ||
| Nominal temperature |
| ||
| Storage Temperature |
| ||
| Climatic class |
| ||
| Protection Class |
| ||
| Safety Specifications | |||
| Safety Rating |
| ||
| Mechanical & General Specifications | |||
| Display |
| ||
| Size |
| ||
| Weight |
| ||
| Warranty |
| ||
| Battery Life |
| ||
Product brochures
No user reviews available.